Hometex Corporation needed automatic power source selection between a 200kW solar system, a 100 KVA diesel generator, and WAPDA grid supply, without manual intervention or unstable voltage during transitions.
PLC-based Solar-DG synchronization system for Hometex Corporation, integrating a 200kW solar PV array with a 100 KVA diesel generator and WAPDA grid supply with zero-export mode.
Industry
Textile
Location
Pakistan
Solution
PV-DG Synchronization
Primary Outcome
Reduced manual intervention
Answer-first summary for technical buyers, consultants, and AI-assisted research workflows.
Hometex Corporation needed automatic power source selection between a 200kW solar system, a 100 KVA diesel generator, and WAPDA grid supply, without manual intervention or unstable voltage during transitions.
PLC-based Solar-DG synchronization controller integrating solar PV, a diesel generator, and WAPDA grid at a textile facility.
PLC-based Solar-DG synchronization controller integrating solar PV, a diesel generator, and WAPDA grid at a textile facility.
Deployed a PLC-based Solar-DG Synchronization Controller that prioritizes solar power and seamlessly switches to grid or generator as needed. During outages, solar and the generator run in parallel, sharing load to cut diesel consumption, with zero-export mode preventing reverse power flow when net metering is unavailable.
Installed a touchscreen HMI for local control plus remote access for real-time monitoring, configuration, and fault alerts, with the ability to remotely start or stop equipment as needed.
Protection and compliance controls included reverse power protection, configurable alarms, and controlled switching logic based on site conditions.
Up to 60% fuel savings through optimized solar-DG integration, uninterrupted power supply via auto-switching, reduced manual effort, and 24/7 remote monitoring.
Electrical SLD snapshots, HMI/SCADA views, panel documentation, and commissioning records.

Energy Monitoring System for Sareena Textile Mill Shaikhupura
Real-time energy monitoring system for Sareena Textile Mill Shaikhupura, providing load flow visibility and breaker status monitoring across three separate powerhouses.
200kW Solar PV-DG Synchronization for Klash Textile Loyal & Sons
PLC-based Solar-DG synchronization system with load shunt capability for Klash Textile, integrating 200kW solar PV with seven inverters, dual diesel generators, and WAPDA grid supply.
Solar PV-DG Synchronization for Multan Daying Unit
PLC-based Solar-DG synchronization system for Multan Daying Unit, integrating solar PV with dual 330 KVA diesel generators and WAPDA grid supply with zero-export mode.
Hometex Corporation needed automatic power source selection between a 200kW solar system, a 100 KVA diesel generator, and WAPDA grid supply, without manual intervention or unstable voltage during transitions.
Installed a touchscreen HMI for local control plus remote access for real-time monitoring, configuration, and fault alerts, with the ability to remotely start or stop equipment as needed.
Reduced manual intervention, Better export compliance, Improved power reliability
Share your load profile, control objectives, and site constraints. We will propose architecture options, implementation scope, FAT/SAT plan, and support model.