Client Challenge
Ghani Value Glass's HFO-powered generators lacked real-time visibility into engine performance, leaving alarms and cylinder temperature trends unmonitored until issues escalated.
A real-time HFO (Heavy Fuel Oil) engine monitoring and SCADA control system delivering live trends, alarms, and generator start-stop automation.
Industry
Manufacturing
Location
Pakistan
Solution
SCADA & Automation
Primary Outcome
Improved operational visibility
Answer-first summary for technical buyers, consultants, and AI-assisted research workflows.
Ghani Value Glass's HFO-powered generators lacked real-time visibility into engine performance, leaving alarms and cylinder temperature trends unmonitored until issues escalated.
Existing site architecture included mixed power sources and required structured integration for stable operations.
Control strategy design, panel-level integration, commissioning workflow, and operational handover.
Automatrix deployed an HFO engine monitoring and control system with SCADA-based visualization for real-time and historical performance tracking.
The system provides real-time trend graphs, a three-tier alarm structure (real-time, unconfirmed, confirmed) with full history logging, bar-graph visualization of cylinder temperatures, and remote generator start/stop control.
Protection and compliance controls included reverse power protection, configurable alarms, and controlled switching logic based on site conditions.
Plant engineers gained early visibility into engine health through live alarms and temperature trends, reducing the risk of unplanned downtime and enabling faster response to abnormal conditions.
Electrical SLD snapshots, HMI/SCADA views, panel documentation, and commissioning records.
PLC-Based Solar-DG Synchronization for CCP Gulbai
A PLC-based Solar-DG Synchronization Controller integrating two SunGrow inverters with a 630 KVA diesel generator, delivering up to 60% fuel savings.
Smart Energy Automation System for Techno Glass, Karachi
An integrated automation system synchronizing three solar inverters, a diesel generator and grid connection into one smart power management solution for a glass manufacturing plant.
Ghani Value Glass's HFO-powered generators lacked real-time visibility into engine performance, leaving alarms and cylinder temperature trends unmonitored until issues escalated.
The system provides real-time trend graphs, a three-tier alarm structure (real-time, unconfirmed, confirmed) with full history logging, bar-graph visualization of cylinder temperatures, and remote generator start/stop control.
Improved operational visibility, Improved fault response readiness
Share your load profile, control objectives, and site constraints. We will propose architecture options, implementation scope, FAT/SAT plan, and support model.